|
Healthcare, Lab & Life Science
|
Valleylab Electrosurgical Generator Force 4B
Patient Ready,Biomed Cert.,W/Accessories,14 day refund
| Start Price |
USD 1,800.00 |
| Current Price |
USD 1,800.00 |
| Time Left |
- |
| Bid Count |
0 |
| Buy It Now Price |
- |
| Reserve Price |
- |
| Start Time |
Sunday, August 17, 2008 |
| End Time |
Monday, August 25, 2008 |
| Location |
loma linda, CA |
|
See more about 'Valleylab Electrosurgical Generator Force 4B'
|
Description
VALLEYLAB ELECTROSURGICAL GENERATOR FORCE 4B-20ECUNIT IS PATIENT READY- NICE AND CLEAN, SEE PICTURES AND CALIBRATION RESULTS FOR YOUR GUARANTEED SATISFACTION.Our items are shipped within the United States within 2 days of payment via UPS/USPS Ground (HI/AK/Other US Territory & International Shipping/Handling Fee Varies ).We do Calibration and Repair of our sold equipment after the warranty period with discount.Also,We offer services of your existing medical equipment. International buyer should inquire first before buying. The Valleylab Force 2 ESU electrosurgical cautery unit provides cutting and coagulation in monopolar or bipolar outputs. Force 2s have audible and visual alarms, including Fault Indicator. The REMâ„¢ (Return Electrode Monitoring) is standard. 300 watts max. output in a Cut setting, 70 watts max. output in Bipolar setting both Precise and Standard, 120 watts max. output in Coagulation setting and 250 Watts max. output in a Blend 1 setting, 200 Watts max. output in Blend 2 setting, and 200 Watts max. in Blend 3 setting. ACCESSORIES INCLUDES:- 1 Cut/Coag ESU Footswitch- 1 Brand New Electro-Surgical Footswitching Pencil with Tip and Holster ( Not seen/included on picture) - 2 Brand New Electro-surgical Handswitching Pencil with Electrode Tip & Holster- 1 Reusable patient plate with REM adaptor & cable- 1 Hospital grade power cord (Built-In)- 5 Hyfrecator Electrolase Electrode Tips- 3 Blade type Electrode Tip: Medtronic #60003CONDITION:This Unit is in Excellent Working Condition.Calibrated, Biomedically Certified and Patient ready with good physical condition.CALIBRATION TEST RESULTS : BEFORE ADJUSTMENT : Manufacturer's specification : +/- 15 % ELECTROSURGICAL GENERATOR : FORCE 4B-20EC S/N : F2E3392B Monopolar @ 300 Ohms rated load. Bipolar @ 100 Ohms rated load. (Measured Output : Watts) (Measured Output:Watts) (Measured Output: Watts) Setting : Pure Cut / Blend 1 / Blend 2 / Blend 3 Setting : Coag Output Setting : Bipolar Output (Watts) (Watts) (Watts) Precise / Std. 300 270.9 - - - 120 121.7 70 71.9 68.0 250 241.5 231.8 - - 100 102.4 60 58.7 57.0 200 199.9 183.9 186.8 188.4 80 82.0 50 51.3 47.6 150 148.0 142.2 135.8 140.1 60 59.3 40 39.7 37.8 100 102.8 91.7 98.7 98.6 40 42.6 30 29.5 29.4 60 58.4 53.6 58.4 57.7 20 22.0 20 19.9 20.1 40 41.3 37.4 39.1 40.4 10 11.5 10 9.4 9.6 20 21.6 19.6 21.4 21.6ELECTRICAL SAFETY TEST :Unit Under Test = Power On Normal Mode: Reverse Mode : Leakage current (Chassis) 23.0 microamp. 30.0 microamp.Leakage current (Earth) 23.0 microamp. 30.0 microamp.Chassis Resistance Measured : 0.08 OhmREMARK(S) : The above unit under test meets manufacturer's specification based on above test results taken during the time of calibration. FREE CONSULTATION:WE OFFER TECHNICAL SERVICES MONDAY TO FRIDAY FROM 9:00 AM TO 5 PM (PACIFIC TIME). PLEASE FEEL FREE TO CONTACT US AT PHONE #: 1 -909-7961148 or Leave your message with your phone No.
Place a Bid!
|
|
|
Search
Categories
More related categories
 |
[home] [sitemap]
|